Chain
Model | Chain |
Controls | Chain (on left or right) |
Design | Flat fold with batten at back |
Headrail Material | Aluminium |
Fabric Composition | Varies according to fabric choice |
Oversize Fabric | Railroad |
Lining | Lightfilter or Blockout |
Chain Design | Plastic or Stainless Steel with Safety chain tensioner supplied |
Child Safety Device | Yes |
Width | 315 to 3048mm |
Height | 610 to 3048mm |
Maximum Size | 9.2 m2 |
Depth Required | 45mm |
Manufacturing Tolerance in Width | +/- 6mm |
Manufacturing Tolerance in Height | + 13mm |
Width Deductions we take (inside mount) | 6mm |
Height Deductions we take (inside mount) | 0mm |
Points to note:
- 'Depth Required' is the clearance required from the front to the back of your window frame for uninterrupted operation of the blind. Please also take into account any window handles or other obstructions that may interfere with the blind.
- Blockout Lining is only available with certain fabrics.
- For blinds installed on the inside of the window frame, please provide the inside window frame size. The factory will take the relevant deductions to ensure the blind fits nicely into your window frame.
- For blinds installed on the outside of the window frame, please provide the exact measurements. No deductions will be taken from your measurements.
- Chain guides will be provided and must be installed to prevent potential chocking hazards.
Cordless
Model | Cordless |
Controls | Fabric handle (back of blind) |
Design | Flat fold with batten at back |
Headrail Material | Fabric wrapped timber |
Fabric Composition | Varies according to fabric choice |
Oversize Fabric | Railroad |
Lining | Light Filter or Blockout |
Width | 518 to 2438mm |
Height | 610 to 2438mm |
Maximum Size | 3.7 m2 |
Depth Required | 45mm. minimum 31 partial reveal |
Manufacturing Tolerance in Width | +/- 6mm |
Manufacturing Tolerance in Height | + 13mm |
Width Deductions we take (inside mount) | 9.5mm |
Height Deductions we take (inside mount) | 0mm |
Points to note:
- 'Depth Required' is the clearance required from the front to the back of your window frame for uninterrupted operation of the blind. Please also take into account any window handles or other obstructions that may interfere with the blind.
- For blinds installed on the inside of the window frame, please provide the inside window frame size. The factory will take the relevant deductions to ensure the blind fits nicely into your window frame.
- For blinds installed on the outside of the window frame, please provide the exact measurements. No deductions will be taken from your measurements.